مشخصات فني


پاور انالایزر Trms RMS 3290 / 3290-10
 قابلیت انتخاب یکی از سه سنسور و یا ترکیبی
اندازه گیری 20 تا 2000 امپر AC/DC و ذخیره تا3000 آمپر پیک
نمایش و ثبت :  
  مقادیر حقیقی AC/DC ، انتخاب خروجی ، اندازه گیری فرکانس ، شکل موج
 3290-10 :
ثبت جریان ،ماکزیمم و مینیمم ،میانگین ، وقابلیت افزایش کابل رابط تا 100 متر   

 

CLAMP ON AC/DC HiTESTER 3290 , 3290-10

CE
CAT III 600 V
For Clamp Sensor
RMS

Sensor is sold separately 
 
 
 All the Functions You Need for Measurement at DC or 1Hz and Up
 
Choice of three sensors (Example combinations)
Measure up to 100 A, 200 A, or 2000 A rated current
Correct measurement for inverter current with AC+DC mode and True RMS rectification
Choice of output (Simultaneous output) Effective value, waveform, frequency, and integral value output
Choice of response time with three steps
Model 3290-10 only with integral current measurement, operating time rate measurement
 
 پاورآنالایزر
Measurement methodDC, AC+DC (True RMS), AC (True RMS/ Average rectified)DC, AC+DC (True RMS), AC (True RMS)
Peak value displayAbsolute value (of waveform peak)Polarities independently (±peak value of waveform, in DC mode)
Separate AC from DC outputSeparate constituent element of AC, DCNone
Output (terminal 1)Current waveform or true RMS value (2 V / setting range), Frequency value (1 VDC / setting range)Current waveform or true RMS value (2 V / setting range)
Output (terminal 2)Rms current/Low-battery warning switchCurrent integral value (1 VDC / setting range)
Integral current measurementNone±, +, - integral, average value
Rate measurementNoneOperating time rate, total measurement time
Timer settingsNone99 hr, 59 min. (for repeated up to 20 times)
Data storageNonePeak, integral value, operating time rate, or other
Basic accuracy at DC current20.00/ 100.0A (using the CT9691 sensor): ±1.3 % rdg. ±0.10 A/ ±0.5 A
20.00/ 200.0A (using the CT9692 sensor): ±1.3 % rdg. ±0.10 A/ ±0.5 A
200.0/ 2000A (using the CT9693 sensor): ±1.8 % rdg. ±1.0 A/ ±5 A
Basic accuracy at AC current
(45 to 66 Hz)
20.00/ 100.0A (using the CT9691 sensor): ±1.3 % rdg. ±0.08 A/ ±0.3 A
20.00/ 200.0A (using the CT9692 sensor): ±1.3 % rdg. ±0.08 A/ ±0.3 A
200.0/ 2000A (using the CT9693 sensor): ±1.3 % rdg. ±0.8 A/ ±3 A
Voltage measurementNone
Frequency measurement1.00Hz to 1000Hz, Basic accuracy: ±0.3% rdg. ±1dgt.
Crest factor2.5 or later, or rated peak value of sensor
Frequency characteristicDC, or 1 Hz to 1 kHz (accuracy guaranteed range)
At monitor output: based on the using sensor
Other functionsSelectable of response time, filter (fc=550 Hz)
Power supplyLR6 (AA) alkaline batteries × 4, Continuous use : 22 hr, or AC adapter 9445-02/-03 (The 3290-10 only: external power supply possible)
Dimensions, mass155 mm (6.10 in) W × 98 mm (3.86 in) H × 47 mm (1.85 in) D, 545 g (19.2 oz)
Supplied accessoriesCarrying strap ×1, LR6 (AA) alkaline batteries × 4, Instruction manual ×1