مشخصات فني


پاور آنالایزر 3169-20/21
 
 
 
 
 

CLAMP ON POWER HiTESTER 3169-20, 3169-21

DCL
marked
DCL
Max. circuit voltage
300-1000V rms insulated wire
RMS
 
 
RS-232C
 

Clamp sensors : Option 
 
 Demand measurement up to 4 circuits, and harmonics measurement simultaneously
 
Simultaneously measure demand and harmonic waveforms that share the same voltage line over 4-circuits
Data can be saved onto a PC card
High-speed and continuous processing to measure individual waveforms
High-speed D/A output for analog graph recording (Model 3169-21)
 
پاورآنالایزر 3169-20/21
Measurement line & number of circuitsSingle-phase 2-wires (4 circuits), Single-phase 3-wires (2 circuits), Three-phases 3-wires (2 or 1 circuit), and Three-phases 4-wires (1 circuit)
Note: 50 or 60 Hz, and that share the same voltage line
Measurement itemsVoltage, Current, Active/ reactive/ apparent power, Active/ reactive power integration, Power factor, Frequency, Harmonic waveform value
Voltage ranges150.00 V to 600.00 V AC, 3 ranges
Current ranges500.00 mA to 5.0000 kA AC (depends on current sensor in use)
Power ranges75.000 W to 900.00 kW (depends on combination of voltage, current range, and measurement line)
Basic accuracyAC Voltage: ±0.2 % rdg. ±0.1 % f.s.
AC Current: ±0.2 % rdg. ±0.1 % f.s. + current sensor accuracy
Active power: ±0.2 % rdg. ±0.1 % f.s. + current sensor accuracy (at power factor = 1)
CLAMP ON SENSOR 9661: ±0.3 % rdg. ±0.01 % f.s. (different from each model)
Measurement methodDigital sampling, PLL synchronization or 50/60 Hz fixed clock
Basic accuracyActive power: ±0.2% rdg. ±0.1% f.s. + clamp-on sensor accuracy (at 45 to 66 Hz)
Display refresh rate2 times /sec (except when using a PC card while accessing the internal memory, or when performing RS-232C communications)
Data save intervalStandard interval: 1 sec to 30 sec, 1 minute to 60 minutes, 13 selects
Fast interval: A single waveform, or 0.1, 0.2, or 0.5 sec (at instant value only)
Frequency characterristicsFundamental waveforms up to the 50th order ±3% f.s. + measurement accuracy (of a 45 to 66 Hz fundamental waveform)
Other functionsError connect check, language selection, display hold, setting backup, power shut off management, key lock, [3169-21 only] D/A output 4 channels, ±5 V DC f.s.)
Power supply100 to 240 V AC, 50/60 Hz, 30 VA max.
Dimensions, mass210 mm (8.27 in) W × 160 mm (6.30 in) H × 60 mm (2.36 in) D, 1.2 kg (42.3 oz)
Supplied accessoriesVOLTAGE CORD L9438-53 ×1 (Black/ Red/ Yellow/ Blue), Power cord ×1, Instruction Manual ×1, Quick Start Manual ×1, CD-R ×1 (RS-232C interface operating manual) ×1, Input cord label ×1, CONNECTION CABLE 9441 ×1 (for the 3169-21 only)
 کاتالوگ.jpg