مشخصات فني

• دقت بالا، کارایی بالا و اندازه گیری و قابل اطمینان• طراحی ایمنی جهت مصارف صنعتی  High Accuracy, High Performance and Reliable Measurements•0.02% basic DC accuracy•Large display with 50,000 counts•Dual display for double indication for AC and DC, V and Hz, etc.•True-RMS Measurements AC and AC+DC•Wide AC Frequency bandwidth from 10Hz to 100kHz *•True-RMS or MEAN value detection mode can be selected *•Fast Peak Hold response time of 250µs•Low-pass filter for motor drive measurements *•Low Power Ω for resistance measurements on sensible electronic circuits by a low and safe test current *•User calibration function* Only for KEW 1062                           Safety design for industrial use•Complies with IEC 61010-1 CAT.III 1000V, CAT.IV 600V•Terminal shutter to prevent incorrect test leads' insertion in current terminals•Very wide operating temperature range from -20 to 55ºCReliable support for data management•Large data internal memoryKEW 1062: 10,000 data (logging), 100 data (manual)KEW 1061: 1,000 data (logging), 100 data (manual)•Download data and Live Monitoring on a PC via the USB interface(Option for USB Communication set)  KEW 1061KEW 1062Detection modeRMSMEAN/RMS (switch)DC V50.000/500.00/2400.0mV/5.0000/50.000/500.00/1000.0V(Input impedance: Approx. 100MΩ [50/500/2400mV], 10MΩ [5/50/500/1000V])|±0.02%rdg±2dgt (Basic accuracy)AC V[RMS]50.000/500.00mV/5.0000/50.000/500.00/1000.0V(Input impedance: 11MΩ|±0.7%rdg±30dgt (Basic accuracy)|±0.4%rdg±30dgt (Basic accuracy)AC V[MEAN] *--50.000/500.00mV/ 5.0000/50.000/500.00/1000.0V(Input impedance:11MΩ10MΩ|±1%rdg±30dgt (Basic accuracy)DCV+ACV5.0000/50.000/500.00/1000.0V(Input impedance: 11MΩ|±1%rdg±10dgt (Basic accuracy)|±0.5%rdg±10dgt (Basic accuracy)DC A500.00/5000.0µA/50.000/500.00mA/5.0000/10.000A|±0.2%rdg±5dgt (Basic accuracy)AC A[RMS]500.00/5000.0µA/50.000/500.00mA/5.0000/10.000A|±1%rdg±20dgt (Basic accuracy)|±0.75%rdg±20dgt|(Basic accuracy)AC A[MEAN] *--500.00/5000.0µA/50.000/500.00mA/ 5.0000/10.000A|±1.5%rdg±20dgt (Basic accuracy)DCA+ACA500.00/5000.0µA/50.000/500.00mA/5.0000/10.000A|±1.5%rdg±10dgt (Basic accuracy)|±1%rdg±10dgt (Basic accuracy)Ω500.00Ω/5.0000/50.000/500.00kΩ/5.0000/50.000MΩ|±0.1%rdg±2dgt (Basic accuracy)|±0.05%rdg±2dgt (Basic accuracy)LowPower-Ω *--5.000/50.00/500.0kΩ/5.000MΩ|±0.2%rdg±3dgt (Basic accuracy)Continuity buzzer500.0Ω (The buzzer turns on for resistances lower than 100±50Ω)Diode test2.4000V|±1%rdg±2dgtOpen curcuit voltage: Capacitance5.000/50.00/500.0nF/5.000/50.00/500.0µF/5.000/50.00mF|±1%rdg±5dgt (Basic accuracy)Frequency2.000~9.999/9.00~99.99/90.0~999.9Hz/0.900~9.999/9.00~99.99kHz|±0.02%rdg±1dgt (Basic accuracy)DUTY10~90%|±1%rdgTemperature-200~1372ºC|±1%rdg±1.5ºC-328~2501.6ºF|±1%rdg±2.0ºF(with the use of K-type Temperature probe)MeasurementfunctionsDC Voltage, AC Voltage, DC Current, AC Current, Resistance, Frequency, Temperature, Capacitor, Duty cycle ratio, Decibel (dBV, dBm), Continuity Check, Diode Test, LowPower-Ω *Other functionsData Hold (D/H), Auto Hold (A/H), Peak Hold * (P/H), Range Hold (R/H), Maximum value (MAX), Minimum value (MIN), Average value (AVG), Zero Adjustment (Capacitor, Resistance), Relative values, Save to Memory, LCD backlightWithstand voltage6,880V/5 sec.ApplicablestandardsIEC 61010-1 CAT.IV 600V, CAT.III 1000V Pollution degree 2,IEC 61010-031, IEC 61326-1 (EMC)Power sourceR6P (1.5V)×4 (Auto power off: approx. 20 minutes)Dimensions192(L)×90(W)×49(D) mmWeightApprox. 560g (including batteries)Accessories7220A (Test leads), R6P×4, Instruction manual,8926 (Fuse [440mA/1000V])×1 (included)8927 (Fuse [10A/1000V])×1 (included)

46785490820306198739.jpg